In this lesson, you learn how to power on and start the local smart thermostat application. The application reports collected data to the logs, including current temperature, ambient noise level, HVAC status (heating, cooling, standby), and room occupation indicator.
The Core2 for AWS device has several sensors that are ready to use. For this tutorial, you collect readings from the temperature sensor and microphone using local application code. The application keeps track of sensor readings and status flags that are used to render a summary to the display.
Your smart thermostat samples the integrated sensors by using code that is created and included in the bundled software components. The first step is capturing the values and printing them out to the logger, before publishing sensor values to AWS IoT Core.
The following sample code illustrates capturing data from the temperature sensor module (MPU6886):
// include libraries for interfacing with the kit's modules
#include "freertos/FreeRTOS.h"
#include "core2forAWS.h"
#include "mpu6886.h"
#include "esp_log.h"
// the application to run on the device
void app_main()
{
// initialize a float to store our temperature reading
float temperature = 0.0f;
// initialize the kit modules
Core2ForAWS_Init();
MPU6886_Init();
// read from the temperature sensor
MPU6886_GetTempData(&temperature);
// convert the reading to Fahrenheit and apply a calibration offset of -50
temperature = (temperature * 1.8) + 32 - 50;
// write the value to the ESP32 logger
ESP_LOGI("thermostat", "measured temperature is: %f", temperature);
}
If you use this code to build, flash, and monitor your device, the device takes one reading from the temperature sensor, writes it to the logger, and stops. To continuously sample every second without blocking other processes, you must create a separate FreeRTOS task and pin it to an MCU core.
The following sample code illustrates continuously collecting temperature readings every 1,000 milliseconds (1 second):
#include "freertos/FreeRTOS.h"
#include "freertos/task.h"
#include "core2forAWS.h"
#include "mpu6886.h"
#include "esp_log.h"
// store our application logic in a task function
void temperature_task(void *arg) {
float temperature = 0.0f;
// loop forever!
for (;;) {
MPU6886_GetTempData(&temperature);
temperature = (temperature * 1.8) + 32 - 50;
ESP_LOGI("thermostat", "measured temperature is: %f", temperature);
// sleep for 1000ms before continuing the loop
vTaskDelay(1000 / portTICK_RATE_MS);
}
}
void app_main()
{
Core2ForAWS_Init();
MPU6886_Init();
// FreeRTOS concept: operations that run in a continuous loop are done in tasks
xTaskCreatePinnedToCore(&temperature_task, "temperature_task", 4096, NULL, 5, NULL, 1);
}
A sample application has already been prepared for you to build and upload to your device using Visual Studio Code (VS Code) and the PlatformIO (PIO) extension.
Complete the following steps to upload the application to your device:
Core2-for-AWS-IoT-EduKit/Smart-Thermostat
folder and choose Open Smart-Thermostat.
Next, you will utilize the local Wi-Fi and AWS endpoint configuration that you established during the CloudConnected Blinky tutorial.
Complete the following steps to copy the configuration from the Blinky project, compile the device firmware, and upload it to your device. (Expand and complete the directions that correspond to your host machine’s operating system):
Validate that your device is configured as intended by reviewing the serial output in the terminal window. Your output should look similar to the following:
I (16128) MAIN: On Device: roomOccupancy false
I (16132) MAIN: On Device: hvacStatus STANDBY
I (16137) MAIN: On Device: temperature 64.057533
I (16143) MAIN: On Device: sound 8
Now that the serial output is configured, continue to Data sync .
AWS IoT Kit now features direct access to
M5Stack Forum
, which is a community-driven, questions-and-answers service. Search re:Post using the
Core2 for AWS
tag to see if your question has been asked and answered. If not, ask a new question using the Core2 for AWS